MTP-24F OS2 TypeB Trunk Cables
The connectivity backbone of every high-density AI GPU rack
| Fiber | OS2 9/125µm Singlemode |
|---|---|
| Connector | MTP® Female 24F |
| Type | TypeB straight-through |
| Jacket | Yellow OFNR 3.0mm round |
| IL / RL | ≤ 0.35 dB | ≥ 60 dB |
A comprehensive range of products built specifically for AI data center deployments. MTP/MPO trunks, breakout harnesses, cassette modules, patch cords, and armored assemblies. 100% tested before shipment.
The connectivity backbone of every high-density AI GPU rack
| Fiber | OS2 9/125µm Singlemode |
|---|---|
| Connector | MTP® Female 24F |
| Type | TypeB straight-through |
| Jacket | Yellow OFNR 3.0mm round |
| IL / RL | ≤ 0.35 dB | ≥ 60 dB |
High-volume backbone cabling for AI data center builds
| Fiber | OS2 9/125µm Singlemode |
|---|---|
| Connector | MTP® Female 12F |
| Type | TypeA and TypeB |
| Jacket | Yellow OFNR 3.0mm round |
| IL / RL | ≤ 0.35 dB | ≥ 60 dB |
Short-reach multimode for 100G and 400G deployments
| Fiber | OM4 50/125µm Multimode — Erika Violet |
|---|---|
| Connector | MTP® Female 12F |
| Type | TypeB straight-through |
| Jacket | Erika Violet OFNR 3.0mm round |
| IL / RL | ≤ 0.35 dB | ≥ 20 dB |
Base-8 architecture for 400G QSFP-DD transceivers
| Fiber | OS2 9/125µm Singlemode |
|---|---|
| Connector | MTP® Female 8F |
| Type | Base-8 pinned and non-pinned |
| Jacket | Yellow OFNR 3.0mm round |
| IL / RL | ≤ 0.35 dB | ≥ 60 dB |
Tool-less high-density patching for AI transceiver platforms
| Fiber | OS2 9/125µm and OM4 50/125µm |
|---|---|
| Connector | LC/UPC duplex, push-pull mechanism for high-density panels |
| Type | Universal transceiver compatibility |
| Jacket | 2.0mm round |
| IL / RL | ≤ 0.35 dB | ≥ 60 dB |
800G AI GPU rack interconnects with 1:2 splitter options
| Fiber | OS2 9/125µm Singlemode |
|---|---|
| Connector | MTP/APC — 800G comparable, straight and 1:2 splitter variants |
| Type | MTP/APC compatible and MTP/APC 1:2 Splitter Jumper |
| Jacket | 3.0mm round (yellow/aqua per variant) |
| IL / RL | ≤ 0.35 dB | ≥ 60 dB |
Fan-out from high-density MTP trunk to individual LC server ports
| Fiber | OS2 9/125µm and OM4 50/125µm |
|---|---|
| Connector | MTP Female trunk end + LC/UPC duplex fan-out legs |
| Type | MTP-24F→12×LC · MTP-12F→6×LC · MTP-8F→4×LC |
| Jacket | Round trunk + individual 2.0mm leg cords |
| IL / RL | ≤ 0.35 dB per path | ≥ 60 dB |
Install once. Every rack expansion is a reorder.
| Fiber | OS2 9/125µm and OM4 50/125µm |
|---|---|
| Connector | MTP-12F or MTP-24F rear input · LC duplex front output |
| Type | 12F and 24F · OS2 and OM4 variants |
| Jacket | 1RU standard module housing |
| IL / RL | ≤ 0.35 dB per path | ≥ 60 dB |
Complete line of adaptors engineered as one-piece housings for reduced insertion loss and high durability.
| LC Adaptors | MU5 Series · stainless clip · flange or flangeless |
|---|---|
| SC Adaptors | Simplex or duplex · flange or flangeless |
| ST Adaptors | Metal housing |
| FC Adaptors | Zirconia ceramic sleeve |
| MTP/MPO Adaptors | Type A/B keyed |
Factory-terminated pigtails for splicing into cable runs or panel termination.
| Construction | Simplex or duplex |
|---|---|
| Fiber | OS1/OS2 singlemode and OM multimode |
| Application | Cable-run splicing and panel termination |
Tool-free polarity exchange without exposing fibers.
| Connector | Duplex LC-LC uniboot |
|---|---|
| Polarity | Tool-free reverse polarity |
| Cable | 1.6mm |
| Polish | PC / SPC / UPC / APC |
Carries both fibers of a duplex link in one jacket for cleaner high-density routing.

| Connector | LC duplex uniboot |
|---|---|
| Fiber | OS1/OS2 singlemode and OM multimode |
| Construction | Two fibers in one jacket |
Reduced connector length for high-density panels and cassettes.

| Connector | Short-body LC boot |
|---|---|
| Construction | Simplex or duplex |
| Application | High-density panels and cassettes |
Uniboot cable with push-pull extractor for confined spaces.
| Connector | LC uniboot |
|---|---|
| Access | Push-pull extractor |
| Boot | Rotating boot |
LED identification helps technicians trace individual fiber or copper patch cords.

| Identification | Integrated LED tracing |
|---|---|
| Connector Options | ST / FC / SC / LC / MTP/MPO |
| Application | Fiber or copper patch-cord identification |
Compact one-to-many breakout cable for space-constrained fiber infrastructure.
| Fiber Count | 12 fibers |
|---|---|
| Fiber Core | 0.25mm |
| Outer Diameter | 3.0mm |
Pre-terminated array assemblies for data centers.

| Assembly | MTP/MPO jumpers and fanouts |
|---|---|
| Fiber | Singlemode or multimode |
| Application | High-density data center links |
High-fiber-count trunk assembly for rapid backbone deployment.
| Capacity | Up to 288 fibers |
|---|---|
| Construction | Pre-terminated trunk harness |
| Application | Rapid backbone deployment |
Transitions MTP/MPO trunk connections to individual fiber connectors.

| Trunk Connector | MTP/MPO |
|---|---|
| Breakout Options | ST / SC / FC / LC |
| Application | Trunk-to-individual connector transition |
Protected routing for high-density patching and faster maintenance.
| Connector | LC or SC |
|---|---|
| Armor | 3.0mm spiral armored |
| Singlemode | APC or UPC |
| Multimode | OM3 or OM4 |
Steel-armored protection for demanding DC environments
| Fiber | OS2 9/125µm and OM4 50/125µm |
|---|---|
| Connector | LC/UPC duplex |
| Type | Steel interlocked armor + LSZH outer jacket |
| Jacket | 4.0mm armored round |
| IL / RL | ≤ 0.35 dB | ≥ 60 dB |
Ultra-high-density cords matched to specific transceiver brand requirements
| Fiber | OS2 9/125µm and OM4 50/125µm |
|---|---|
| Connector | CS/SN EZ Flip, MMC/MDC — very small form factor |
| Type | Transceiver-brand-specific compatibility |
| Jacket | 2.0mm round |
| IL / RL | ≤ 0.35 dB | ≥ 60 dB |
Any spec. Any length. Your labeling.
| Fiber | All types including G.657A2 bend-insensitive and OM5 wideband multimode |
|---|---|
| Connector | Any connector type or combination |
| Type | LSZH plenum · Pre-tested with PDF cert · Custom labeling |
| Jacket | OFNR / OFNP / LSZH / Armored — your choice |
| IL / RL | Per project spec |
High-speed copper connectivity for 40GBASE-T and 25GBASE-T links up to 30m.

| Conductor | 24/7 AWG stranded |
|---|---|
| Verification | GHMT-verified CAT8 |
| Performance | 40GBASE-T / 25GBASE-T up to 30m |
Built-in LED tracing identifies a connection in 20–40 seconds.
| Categories | Cat.6 / Cat.6A |
|---|---|
| Shielding | S/FTP or U/UTP |
| Identification | Built-in LED · 20–40 second trace |
Color-coded copper patching with a durable connector system.
| Categories | Cat.5E through Cat.6A |
|---|---|
| Identification | 7 color-clip options |
| Connector | Gold-plated RJ45 |
Reduced-diameter Scorpion patch cord for high-density routing.
| Categories | Cat.5E through Cat.6A |
|---|---|
| Profile | Reduced diameter |
| Identification | 7 color-clip options |
Flexible color-coded patching for copper network connections.
| Categories | Cat.5E through Cat.6A |
|---|---|
| Identification | 7 color options |
| Application | Data center and enterprise patching |
Slim-profile copper patch cord for high-density pathways.

| Categories | Cat.5E through Cat.6A |
|---|---|
| Profile | Slim profile |
| Identification | 7 color options |
Slim copper patch cord with a rotatable connector clip for flexible routing.

| Category | Cat.6 |
|---|---|
| Conductor | 28AWG |
| Construction | U/UTP |
| Clip | Rotatable design |
Cat.6/Cat.6A copper patch cord with a rotatable ID clip for flexible identification.
| Categories | Cat.6 / Cat.6A |
|---|---|
| Clip | Rotatable ID clip |
| Documentation | Product-specific documentation available |
Copper patch cord with antibacterial surface properties for sensitive environments.
| Categories | Cat.5E through Cat.6A |
|---|---|
| Property | Antibacterial surface |
| Documentation | ISO 22196 documentation available |
Purpose-built rack architecture engineered for AI workloads. Launching October 2026.
| Application | Next-generation AI GPU and compute racks |
|---|---|
| Architecture | ORV3-compatible rack design |
| Integration | Pre-wired optical infrastructure optimized for AI workloads |
| Status | Under development — specifications subject to final release |
| Launch | October 2026 |
Every Zelyion product is built to ANSI/TIA-568.3-D, 100% tested before shipment, and built specifically for high-density AI data center deployments. MTP/MPO trunks, breakout harnesses, cassette modules — the three products every AI rack needs, from a single source.
Request a Quote →